5. Under [Notice setup of an alarm log], enter the IP address or the host name
*1
of the SMTP server (outgoing
mail server).
• An IPv6 address can be entered.
• This feature cannot transfer images to web-based mail servers, such as Hotmail.
6. Enter the port number used by the server. (Port 25 is normally used for sending E-mail.)
7. Enter the reply E-mail address
*2
that will be shown to the recipient as the sender of the E-mail.
• In an effort to reduce spam, many ISPs block E-mail sent through the SMTP server from an E-mail
address that is not associated with the SMTP server, therefore, we recommend entering the E-mail
address assigned to you by your ISP.
8. Enter the destination E-mail address
*2
. Up to 3 addresses can be entered.
9. Enter the subject
*2
that will be displayed in E-mail messages sent by the camera (max. 44 characters).
10. Under [How to authenticate], select the authentication method your ISP requires for sending E-mail, and
enter the appropriate settings if necessary.
– [No authentication]: Select this option if the outgoing E-mail server does not require authentication
when sending E-mail messages.
– [POP before SMTP authentication]: Select this option if the outgoing E-mail server requires POP before
SMTP authentication when sending E-mail messages.The following settings are also necessary. Enter
the settings as you would for receiving E-mail.
a. Enter the IP address or the host name
*1
of the POP3 server (incoming mail server).
• An IPv6 address can be entered.
b. Enter the port number used by the server. (Port 110 is normally used for POP3.)
c. Enter the login ID
*2
(user name) required to access the server (max. 63 characters).
d. Enter the password
*2
required to access the server (max. 63 characters).
– [SMTP authentication]: Select this option if the outgoing E-mail server requires SMTP authentication
when sending E-mail messages.The following settings are also necessary. Enter the settings as you
would for sending E-mail.
a. Enter the login ID
*2
(user name) required to access the server (max. 63 characters).
b. Enter the password
*2
required to access the server (max. 63 characters).
60 Operating Instructions