330
DP-C405/C305/C265
FEB 2008Ver. 1.1
E2-10 System
Console Drive
Motor Rotation
The rotation of the
System Console
Drive Motor is not
being detected within
a predetermined time.
Paper Tray 1. Check the System Console Cable
connection.
2. Drive Mechanism is defective.
3. Check the Drive Motor connector.
4. Drive Motor is defective.
5. Check the CST PCB connector.
6. CST PCB is defective.
7. Check the LVPS connector.
8. LVPS is defective.
9. Check the EC PCB connector.
10.EC PCB is defective.
E3: Development System Error Codes
Code Function Contents Section Check Points
E3-14 STR High
Voltage Power
Supply Leak
STR High Voltage
leak is detected.
STR 1. STR Terminal is contaminated with Toner.
2. STR Terminal is loose.
3. HVPS is defective.
4. EC PCB is defective.
E3-22 Toner Cartridge
Fan Rotation
1. The rotation of the
Toner Cartridge
Fan is not being
detected within a
predetermined
time.
2. Toner Cartridge
Fan keeps rotating
after a
predetermined time
has lapsed.
Toner
Cartridge
Fan
1. Check the Fan connector.
2. Fan is defective.
3. Check the EC PCB connector (CN510).
4. EC PCB is defective.
E3-26 OPC Drum
Motor 1
Rotation (Y/M/
C)
1. The rotation of the
OPC Drum Motor 1
(Y/M/C) is not
being detected
within a
predetermined
time.
2. OPC Drum Motor 1
(Y/M/C) keeps
rotating after a
predetermined time
has lapsed.
OPC Drum
Motor
1. Check the Motor connector.
2. Motor is defective.
3. Check the EC PCB connector.
4. EC PCB is defective.
5. Y/M/C Drum Drive Mechanism is
defective.
6. Y/M/C Drum Unit is defective.
E3-27 OPC Drum
Motor 2
Rotation (BK)
1. The rotation of the
OPC Drum Motor 2
(BK) is not being
detected within a
predetermined
time.
2. OPC Drum Motor 2
(BK) keeps rotating
after a
predetermined time
has lapsed.
OPC Drum
Motor
1. Check the Motor connector.
2. Motor is defective.
3. Check the EC PCB connector.
4. EC PCB is defective.
5. BK Drum Drive Mechanism is defective.
6. BK Drum Unit is defective.
E2: Lift DC Motor Error Codes
Code Function Contents Section Check Points

Table of Contents