332
DP-C405/C305/C265
FEB 2008Ver. 1.1
E3-33 Toner Cartridge
Drive Motor
Rotation (Y)
The rotation of the
Toner Cartridge Drive
Motor (Y) is not being
detected within a
predetermined time.
Toner
Cartridge
Motor
1. Toner Cartridge is jamming.
(Shake the Toner Cartridge briskly to
loosen the contents)
2. Check the Motor connector.
3. Motor is defective.
4. Motor mechanism is defective.
5. Check the EC PCB connector.
6. EC PCB is defective. (Check F8 for E3-
35,36 F9 for E3-33,34)
7. Motor mechanism is defective.
E3-34 Toner Cartridge
Drive Motor
Rotation (M)
The rotation of the
Toner Cartridge Drive
Motor (M) is not being
detected within a
predetermined time.
Toner
Cartridge
Motor
E3-35 Toner Cartridge
Drive Motor
Rotation (C)
The rotation of the
Toner Cartridge Drive
Motor (C) is not being
detected within a
predetermined time.
Toner
Cartridge
Motor
E3-36 Toner Cartridge
Drive Motor
Rotation (BK)
The rotation of the
Toner Cartridge Drive
Motor (BK) is not
being detected within
a predetermined time.
Toner
Cartridge
Motor
E3-37 FTR Motor
Rotation
FTR Motor is not
rotating.
FTR Motor 1. Check the EC PCB connector.
2. EC PCB is defective. (Check F12)
3. MOTDRV PCB is defective. (Check F4 for
E3-37, F1 for E3-38)
E3-38 STR Motor
Rotation
STR Motor is not
rotating.
STR Motor
E3-63 FTR Cam
Position Error
The FTR Cam
Position Sensor is not
actuating within a
predetermined time.
(FTR Cam Position
detection value is
abnormal)
FTR 1. Check the FTR Cam Motor connector.
2. FTR Cam Motor is defective.
3. Check the MOTDRV PCB connector.
4. MOTDRV PCB is defective. (Check F4)
5. Check the FTR Cam Sensor 1 or Sensor
2 connector.
6. FTR Cam Sensor 1 or Sensor 2 is
defective.
7. Check the EC PCB connector.
8. EC PCB is defective. (Check F12)
9. FTR Cam Drive mechanism is defective.
E3-64 STR Cam
Position Error
The STR Cam
Position Sensor is not
actuating within a
predetermined time.
(STR Cam Position
detection value is
abnormal)
STR 1. Check the STR Cam Motor connector.
2. STR Cam Motor is defective.
3. Check the MOTDRV PCB connector.
4. MOTDRV PCB is defective. (
Check F1)
5. Check the STR Cam Sensor 1 or Sensor
2 connector.
6. STR Cam Sensor 1 or Sensor 2 is
defective.
7. Check the EC PCB connector.
8. EC PCB is defective. (Check F12)
9. STR Cam Drive mechanism is defective.
E3-65 STR Monitor
Current Read
Error
Not Used STR 1. STR Connection Error.
2. STR HVPS is abnormal.
3. Check the STR HVPS connector.
E3-66 FTR (Y) Monitor
Voltage Read
Error
Not Used FTR 1. FTR (Y) Connection Error.
2. FTR (Y) HVPS is abnormal.
3. Check the FTR (Y) HVPS connector.
E3: Development System Error Codes
Code Function Contents Section Check Points