334
DP-C405/C305/C265
FEB 2008Ver. 1.1
E3-89 Color
Registration
Detection Error
Color Registration
Pattern value is
abnormal.
(Value is less than
predetermined)
Color
Registration
1. IT Belt surface is scratched or dirty.
2. OPC Drum is scratched or dirty.
3. LSU Shutter Open-Close is abnormal.
4. EC PCB is defective.
5. Sensor PCB is defective.
E3-90 TDC Sensor (Y)
Calibration
Error
When F8-09/11 is
performed, the TDC
Sensor output (Y) is
abnormal.
TDC 1. Check the Toner Sensor connector.
2. Toner Sensor is defective.
3. Check the EC PCB connector.
4. EC PCB is defective. (Check F14)
E3-91 TDC Sensor
(M) Calibration
Error
When F8-09/11 is
performed, the TDC
Sensor output (M) is
abnormal.
TDC
E3-92 TDC Sensor (C)
Calibration
Error
When F8-09/11 is
performed, the TDC
Sensor output (C) is
abnormal.
TDC
E3-93 TDC Sensor
(BK) Calibration
Error
When F8-09/11 is
performed, the TDC
Sensor output (BK) is
abnormal.
TDC
E3-94 IT Belt Color
Density
Reading is
Abnormal
(Right)
IT Belt color
registration density
reading for Toner
Registration Sensor
(Right) is abnormal.
IT Belt IT Belt surface is scratched or contaminated
with dirt.
E3-95 IT Belt Color
Density
Reading is
Abnormal (Left)
IT Belt color
registration density
reading for Toner
Registration Sensor
(Left) is abnormal.
IT Belt
E3-96 IT Belt Color
Density
Reading is
Abnormal
(Center)
IT Belt color
registration density
reading for Toner
Registration Sensor
(Center) is abnormal.
IT Belt
E4: Induction Heating (IH) Fuser Unit Error Codes
Code Function Contents Section Check Points
E4-01 Fuser Warm-up
Temperature
The Power is turned
OFF/ON after E4
Fuser Error occurs.
Fuser 1. Fuser Unit is defective.
2. Induction Heating (IH) Unit is defective.
3. Thermistor is defective.
4. Check the EC PCB connector.
5. EC PCB is defective.
E3: Development System Error Codes
Code Function Contents Section Check Points