EasyManua.ls Logo

Panasonic KX-HDV130

Panasonic KX-HDV130
388 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Default Value 0
Web User Interface Reference Threshold MOS-LQ (Critical)
ALERT_REPORT_MOSQ_WARNING
Value Format INTEGER
Description Specifies the warning criteria to send VQ report at the time of
occurring the MOSQ.
Value Range 0–40
Default Value 0
Web User Interface Reference Threshold MOS-LQ (Warning)
ALERT_REPORT_DELAY_CRITICAL
Value Format INTEGER
Description Specifies the critical criteria to send VQ report at the time of occurring
the delay.
Value Range 0–2000
Default Value 0
Web User Interface Reference Threshold Delay (Critical)
ALERT_REPORT_DELAY_WARNING
Value Format INTEGER
Description Specifies the warning criteria to send VQ report at the time of
occurring the delay.
Value Range 0–2000
Default Value 0
Web User Interface Reference Threshold Delay (Warning)
VQREPORT_SIGNAL_COMPRESSION
Value Format BOOLEAN
Description Specifies whether to use signal compression for sending VQ report.
Value Range
Y: Enable
N: Disable
Default Value
N
VQREPORT_SEND_OPT_CODEC_ENABLE
Value Format BOOLEAN
Description Specifies whether to enable the sending of VQREPORT (SIP-
PUBLISH) when the codec is changed.
Value Range
Y: Send VQREPORT when a change of codec is detected
N: Send VQREPORT at the end of a conversation
5.3.28 VQ Report by PUBLISH
Document Version: 2017-07 Administrator Guide 303