EasyManua.ls Logo

Panasonic KX-NS500 - Connection of Extensions; Maximum Cabling Distances of the Extension Wiring (Twisted Cable)

Panasonic KX-NS500
338 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.8 Connection of Extensions
4.8.1 Maximum Cabling Distances of the Extension Wiring
(Twisted Cable)
Cable Maximum Distance
ø 0.4 mm: 222 m
ø 0.5 mm: 347 m
ø 0.6 mm: 500 m
CAT 5: 347 m
Cable Maximum Distance
ø 0.4 mm: 140 m
ø 0.5 mm: 229 m
ø 0.6 mm: 360 m
CAT 5:
229 m
Cable Maximum Distance
ø 0.4 mm:
698 m
ø 0.5 mm:
1128 m
ø 0.6 mm:
1798 m
CAT 5: 1128 m
SLT
APT and DSS Console
PT-interface CS
DPT
Cable Maximum Distance
ø 0.4 mm: 500 m
ø 0.5 mm: 720 m
ø 0.6 mm: 830 m
CAT 5: 720 m
Notice
The maximum cabling distance may vary depending on the conditions.
PT-interface
CS
DPT APT
DSS
Console
SLT
DHLC4 Card
ü ü ü ü ü
MCSLC8, MCSLC16
cards
ü
DLC2, DLC8, DLC16
cards
ü ü ü
"ü" indicates that the extension card supports the terminal.