Panasonic KX-NS500 - Page 185

Panasonic KX-NS500
338 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Baud Rate (bps)
Flow Control
Command
5. Enter Password.
6. Click Connect button.
Connection via PRI23 Card (KX-NS5290), PRI30/E1 Card (KX-NS5290CE),
BRI2 Card (KX-NS5282
), or BRI4 Card (KX-NS5284)
Note
The PRI30/E1 card is used as an example in the following illustration.
PC
ISDN MODEM
ISDN Line
Network
PRI30/E1 Card (KX-NS5290CE) is installed
in KX-NS500
To connect a PC to the Main Unit
1. Start Off-line WebMC launcher.
2. Click the Connect-Online Mode(C) button.
3. Select the ISDN Remote tab.
4. In Telephone Number, enter a telephone number.
5. In Password, enter the password.
6. Click the Connect button.
MNT Port
By connecting a USB-LAN adaptor to the USB port you can access the PBX over a LAN.
Notice
When connecting the PC to the MNT port, if the PC is set to obtain the IP address automatically, the
IP address of the PC will be set to an appropriate IP address to establish a connection to the PBX.
Only recommended USB-LAN adaptors can be used. For information on recommended products,
consult you dealer.
Installation Manual 185
5.2 PC Connection