2.7 Connection of DECT Portable Stations
98 Installation Manual
e. Make sure that the radio signal strength level is greater than "3" at any location within the service
area required by the user.
4. Finish the site survey
Refer to "2.7.6 After Site Survey".
a. Return all DIP switches of each CS to the OFF position, and stop supplying power.
b. Turn off the PS.
5. Connect the CS and PS to the Hybrid IP-PBX and test the operation
Refer to "2.7.7 Connecting a Cell Station to the Hybrid IP-PBX".
a. Connect the CSs to the Hybrid IP-PBX.
b. Register the PSs to the Hybrid IP-PBX.
c. Walk around the service area while having a conversation using a registered PS. If noise is
frequent or conversations disconnect, relocate the CSs or install an additional CS.
6. Mount the CS on the wall
Refer to "2.7.8 Wall Mounting".
a. If there are no problems in testing, mount the CS on the wall.