147
Model No. Item Setting Value Setting Remarks
000 Clear address
00
Indoor unit address
(Central control address)
001 ~ 200
Set address
[001] ~ [200]
000 Not set (Clear)
001 Low sound level 1
002 Low sound level 2
02 Low sound at night
003 Low sound level 3
000 Clear address
06 Outdoor unit address
001 ~ 199
Set address
[001] ~ [199]
000 -
10
Automatic address resetting for group
control
001 Reset address
000 Indoor unit thermistor
11 Switching the thermistor
001 Remote control thermistor
000 -
001 Available (Non-linking)
002 Available (linking OFF)
12 Ventilation unit control (Option)
003 Available (linking ON/OFF)
Note: 1. The default setting at shipment is “000”.
SETTING INDOOR UNIT ADDRESS (Central control address)
• Checking, setting and clearing the indoor unit address (Central control address) can be performed.
• It is possible to set the address value from “001” to “200”. Setting the address to “000” clears it.
○
1
Perform the steps (1) and (2) from the local setting procedure.
For step (2), select “00”.
○
2
Press the SELECT switch to check the indoor unit address.
* For group control, choose the air conditioner No. with the UP / DOWN (TEMP & A/C No.) switches.
○
3
To check the address only, press the TEST RUN switch to return to the normal display.
To set and clear the address, press the SELECT switch again and it will display the address settings for the
indoor unit.
○
4
The UP / DOWN (TIMER) switches set the indoor unit address.
○
5
Once the indoor unit address is fixed with the SET switch, and it will return to the check display screen for the
indoor unit address.
* It is possible to choose a different air conditioner No. with the UP / DOWN
(TEMP & A/C No.) switches under
group control. After selecting a different air conditioner No., return to step
○
3 of the procedure.
○
6
After checking the indoor unit address, press the TEST RUN switch to return to the normal display.
SETTING OUTDOOR UNIT ADDRESS
• Checking, setting and clearing the outdoor unit address can be performed.
• It is possible to set the address value from “001” to “199”. Setting the address to “000” clears it.
○
1
Perform the steps (1) and (2) from the local setting procedure.
For step (2), select “06”.
○
2
Press the SELECT switch to check the outdoor unit address.
* For group control, choose the air conditioner No. with the UP / DOWN
(TEMP & A/C No.) switches.
○
3
To check the address only, press the TEST RUN switch to return to the normal display.
To set and clear the address, press the SELECT
switch again and it will display the address settings for the
outdoor unit.
○
4
The UP / DOWN (TIMER) switches set the outdoor unit address.
○
5
Once the outdoor unit address is fixed with the SET switch, and it will return to the check display screen for the
outdoor unit address.
* It is possible to choose a different air conditioner No. with the UP / DOWN
(TEMP & A/C No.) switches under
group control. After selecting a different air conditioner No., return to step
○
3 of the procedure.
○