361
20.7.5 Low Static Pressure Hide-away Type Indoor Unit
S-45MA1E5
5mmAq(49Pa)
QPQPQP
標準 15.0 49.0 13.0 32.1 11.0 25.6
下限 13.5 74.1 12.0 57.2 10.2 47.8
ター 15.0 49.0 13.0 32.1 11.0 25.6
上限 16.5 11.1 14.0 6.8 11.6 3.5
7mmAq(69Pa)
QPQPQP
標準 15.0 69.0 13.0 50.0 11.0 41.0
下限 13.5 86.3 12.0 70.9 10.2 60.0
ター 15.0 69.0 13.0 50.0 11.0 41.0
上限 16.5 37.3 14.0 27.0 11.6 19.7
HML
HML
Standard air flow volume:H15、M13、L11m3/min
0
10
20
30
40
50
60
70
80
90
100
10 11 12 13 14 15 16 17 18 19 20
Air flow volume m3/min
External static pressure Pa
5mmAq(49Pa) 7mmAq(69Pa)
S-56MA1E5
5mmAq(49Pa)
QPQPQP
標準 15.0 49.0 13.0 32.1 11.0 25.6
下限 13.5 74.1 12.0 57.2 10.2 47.8
ター 15.0 49.0 13.0 32.1 11.0 25.6
上限 16.5 11.1 14.0 6.8 11.6 3.5
7mmAq(69Pa)
QPQPQP
15.0 69.0 13.0 50.0 11.0 41.0
下限 13.5 86.3 12.0 70.9 10.2 60.0
ター 15.0 69.0 13.0 50.0 11.0 41.0
上限 16.5 37.3 14.0 27.0 11.6 19.7
HML
HML
Standard air flow volume:H15、M13、L11m3/min
0
10
20
30
40
50
60
70
80
90
100
10 11 12 13 14 15 16 17 18 19 20
Air flow volume m3/min
External static pressure Pa
5mmAq(49Pa) 7mmAq(69Pa)