28
TH-103PF12E
4. Disconnect the connector (DS14).
5. Remove 10 screws and then remove the Fixed Plate
6. Disconnect the connectors (DS2, DS4, DS6, DS9, DS15).
7. Remove the flexible cables from the connectors(DS1,
DS3).
8. Remove 3 screws and then remove DS-Board.
9.8. Removal of HX-Board
1. Remove the Slot Case.
(Refer to Removal of DS-Board)
2. Disconnect the connector (HX1).
3. Remove 4 Hexagonal-Head screws and 2 screws and
then remove HX-Board.
9.9. Removal of DN-Board
Check that no bright points appears by Ve Life adjustment
after both D and DN board exchange.
1. Disconnect the connectors (DN3, DN5, DN9).
2. Remove the flexible cables from the connectors (DN1,
DN2)
3. Remove 4 screws and then remove DN-Board.
Note:
A re-setup of the destination is performed by MS
mode after DN-Board exchange.

Table of Contents