51
TH-103PF12E
10.1.2. Initialization Pulse Adjust
1. Set Aging pattern (white pattern signal) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
3. Connect Oscilloscope to TPSC1 and adjust VR16601 for 125V ± 5V.
Test Point Volume Level
TPSC1 (SC) VR16601 (SC) 125V ± 5V
at 50
µs period on the down slope.