- 13 -
ACCESS CODES
The Digiplex control panel supports the following
access codes:
• 63 User Access Codes
• 1 System Master Code
• 1 Installer Code.
4.1 Installer Code
Section [800]
{Default: 000000} The Installer Code is used to enter
the control panel’s programming mode, which allows
you to program all the features, options and
commands of the control panel and any modules
connected to the DIGI-BUS. The Installer Code can not
program the User Access Codes. The Installer Code
is six digits in length where each digit can be any
value from 0-9.
Press & Hold [0] + [INSTALLER CODE] + [800] + New
6-digit [INSTALLER CODE]
4.2 ACCESS CODE LENGTH
Section [504] – Options [2] & [3]
[2] [3] Option
Off Off 4-Digit Access Codes
Off On 6-Digit Access Codes
On Off Same as On/On
On On Flexible Access Codes
Access codes can be between 1 and
6 digits in length. When programming
flexible access codes with less than 6-
digits, press the [ENTER] key.
When you change the Access Code Length from 4
digits to 6 digits, the control panel will automatically
add the last 2 digits by using the first 2 digits. For
example, if your Access Code is 1234 and you switch
to 6 digits the code will become 123412. When you
change the Access Code Length from 6 digits to 4
digits, the control panel will automatically remove the
last 2 digits.
4.3 SYSTEM MASTER CODE
{Default: 123456} With the System Master Code a
user can use any of the available arming methods
with access to all partitions and can program all User
Access Codes, User Options and User Partition
Assignments. The System Master Code can use
any digits from 0 to 9. The length of the System
Master Code is determined by the Access Code
Length feature (see section 4.2 above).
The System Master Code cannot be set to
less than 4-digits in length.
4.3.1 System Master Code Reset
Using the Installer Code, enter section [950] to
reset the System Master Code to 123456.
The Installer can program the User Code
Options and Partition Assignment but
cannot program the System Master Code or
the User Access Codes.
4.4 USER OPTIONS
The User Options define how each User Access
Code can arm or disarm the system. Regardless of
these settings, all users can Regular Arm (see
section 14) assigned partitions (see section 4.5 of
this manual) and all users except those with the
Arm Only option (see section 4.4.4) can disarm an
assigned partition. Select one or more of the
options described in the following sub-sections for
each User Access Code as shown in figure 4.1 on
the following page. The System Master Code or a
user with the Master Feature enabled can also
program the User Options using a different method
of programming (see section 14).
4.4.1 Master Feature
Sections [802] to [864] – Options [1] & [2]
[1] [2] Option
Off Off Master Feature Disabled
Master Feature Disabled
On Off Users can create or modify User
Access Codes that have the same
partition assignment.
On On Users can create or modify User
Access Codes with the same partition
assignment and program the User
Options & Partition Assignment
(assigns only partitions the Master
Feature Code has access to).