5.3 Connecting Sensors
Before the device can be used to take measurements, the sensors required for
the measurement must be connected.
5.3.1 Connecting CAN Sensors
Fig.8 Connecting CAN sensors
Connect the sensors in the following sequence:
1 Connect the sensors on the application side (e.g. hydraulic connection).
2 Connect the sensors to a bus cable or a Y-junction (refer to figure). Use a
terminating resistor before the last sensor.
3 Connect a bus cable to the corresponding port on the device.
IMPORTANT
The device does not record data from sensors which are connected while a
measurement is in progress.
Restart the measurements in order to record data from sensors just connect-
ed. Measuring data from sensors which are disconnected while a measure-
ment is in progress is recorded by the device to the moment of disconnection.
23
The Parker Service Master COMPACT V1.0/02/24
Starting Up