12.5 Inputs
12.5.1 CAN (SCM-370-1-05 and SCM-370-2-05 only)
Designation Properties
Plug 5-pin, M12×1, panel connector, terminating resistor permanently
installed
sensors Max. 6 Parker CAN sensors with sensor detection
Scanning rate Up to 4 sensors: 1 ms, 5-6 sensors: 2 ms
12.5.2 Analog (SCM-370-0-02 only)
Designation Properties
Plug 5-pin, push-pull, combination panel plug/socket
sensors 4 sensor inputs (up to 8 analog measuring channels) with sensor de-
tection (p/T/Q/n) for SensoControl® diagnostic sensors
Scanning rate 1 ms = 1,000 measured values/sec.
Accuracy 0.1 % FS
12.5.3 AUX
Designation Properties
Plug M12×1, 5 pin socket
sensors 1 connection with 2 inputs (analog) for external sensors for measur-
ing current and voltage
Voltage measuring range -10…+10 V
DC
Current measuring range 0/4…20 mA
Supply of ext. sensors +24…+24 V
DC
/max. 100 mA (for both inputs)
Scanning rate 1 ms = 1,.000 measured values/s
FAST-MODE 0.1 ms = 10,000 measured values/s
12.5.4 Calculation Channels
Designation Properties
Number 2
Connection Virtual
Functions Subtraction, Addition, Multiplication, Power, Volume