7.6.1 Setting Calculation Channels
In the CALC-1 and CALC-2 menus you will find settings for parameterizing the
IN-2 channel of the device.
Fig.51 Set calculation channels
The following functions are available:
Designation Description
Channel Name Enter the channel name
Formula Set the calculation type or formula:
Subtraction, Addition, Power 1, Power 2, Volume,
Multiply
P1 Select the input signal
(depending on the formula selected)
P2 Select the input signal
(depending on the formula selected)
Q Select the input signal
(depending on the formula selected)