12. Technical Data
This chapter provides information on the technical data of the device.
12.1 Device Models
Device
SCM-370-0-02 4 inputs for Parker analog sensors
2 inputs for standard industrial sensors
SCM-370-1-05 Interface for up to 6 Parker CAN sensors
2 inputs for standard industrial sensors
SCM-370-2-05 Interface for up to 6 Parker CAN sensors
K-SCM-370-0-02 Analog AUX device version, calibrated with calibration certificate according to ISO
9001
K-SCM-370-1-05 CAN AUX device version, calibrated with calibration certificate according to ISO
9001
K-SCM-370-2-05 CAN device version, calibrated with calibration certificate according to ISO 9001
All versions include USB memory stick and USB cable (USB-C to USB-A).
12.2 Mechanical Data
Designation Property
Dimensions (W × H × D) 215 × 60 × 154 mm
Weight Approx. 850 g
Type of protection IP 65 (EN 60529:1989 +A1:1999 + A2:2013), all screw connections
must be provided with sensors or protective caps
Ambient temperature -20…+50° C
Storage temperature -30…+80°C
Relative humidity max. 95 %, non-condensing
Environmental impact test Drop test 1 m (EN 60068-2-31:2008)
Housing ABS/PC
Protective casing TPE, thermoplastic elastomer
VESA holder 75 mm×75 mm
12.3 Display Data
Designation Property
Resolution 800×480pixels
Size 4.3"
Brightness 700 cd
93