Parker Hannifin S.p.A. - Divisione S.B.C. “SPD” User’s Manual
36
Par.
Description
Def. Type/
Notes
Pb94.10
Value comparator. (See paragraph Functions and
operating modes)
R/W
Pb94.11
Value comparator. (See Further functions paragraph)
R/W
Pb99.0
See picoPLC
Pb99.1
See picoPLC
Pb99.2
See picoPLC
Pb99.3
See picoPLC
Pb99.6
Extended menu enable. If set to 1, the extended menu is
enabled.
0 R/W
M
Pb99.7
Safety.
If set to 1, parameters cannot be modified .
0 R/W
M
Pb99.8
UV auto reset If set to 1, the under-voltage alarm will
automatically be set to 0 when power returns.
0 R/W
M
Pb99.10
Command to reset alarms. (Con Pr230) 24;If the alarm
continues, it is displayed on the screen. This command
cannot be used if there is a check-sum error (Pr23 = 10,
11). In this case, it is necessary to set the default
parameters (b99.12) and then reset the alarm.
0 R/W
Pb99.11
Default values of the parameters in operating mode.
This command sets the operating mode parameters to the
default values. The command is executed only if b 40.2=
0.
0 R/W
Pb99.12
Default values. This command sets all parameters to the
default values and sets those used by the operating mode
to 0. Furthermore, it sets the pico-PLC program as
described in Appendix F Appendix D:. There is a check-
sum alarm, Pr23 and Pr24 will be set to 0, thereby
permitting the alarm to be reset. The command is
executed only if b 99.13=0.
0 R/W
M
Pb99.13
See picoPLC
Pb99.14
Storing of the pico-PLC instructions. This command
saves the pico-PLC program. It cannot be used if a check-
sum alarm has been indicated. In this case, it is necessary
to set the default parameters, reset the alarm and then
store the new parameters.
0 R/W
Pb99.15
Storing of parameters. This command stores all
parameters. It cannot be used if a check-sum alarm has
been indicated. In this case, it is necessary to set the
default parameters, reset the alarm and then store the new
parameters.
0 R/W