User Guide 15
Inputs
Ground level shift
To reduce ground level shift:
1. Dedicate one of the 4 system ground inputs (GND) to sensors that have
dedicated ground wires, and connect all sensor grounds to this system ground
input.
2. Splice the other system ground inputs together in the vehicle harness (close to
the connector) to provide a better ground for the noisier low-side outputs and
digital circuits.
3. Position the sensor’s ground connection near the system ground connections
to ensure that the signal remains within the digital activation range of the
input.
Note 1: The system ground inputs are rated for low-current signals, which
ensures the sensor's ground is very close in voltage potential to the system
ground.
Note 2: Sensors that don’t have a dedicated ground wire are typically
grounded to the vehicle chassis through the sensor’s body.
Internal to product
Sensor Power
Resistive Sensor
Pull-up
Resistor
Active Sensor
Analog Input
Analog Input
Figure 5: Analog input ground shift connection for sensors that have dedicated ground wires