PRUNING SHEARS C3X
26_176804-B
5.2. ACTIV’ SECURITY ACTIVATED
Activ' Security only works when the user is wearing conductive gloves PELLENC or when they are working without
gloves.
If the user is wearing other types of gloves, the tool will only start if the Activ' Security has been deactivated
beforehand.
See 5.1. Activ'Security deactivated, page 18.
For more information on Activ' Security, see 3.3. Presentation of Activ' Security, page 15.
5.2.1. ACTIV' SECURITY TOOL ACTIVATED
1. Press the ON/OFF button (1).
Note
The tool will emit a series of beeps to indicate
that it is switching on.
The Activ' Security LED flashes red while
waiting for calibration information.
2. Hold the tool in your hand, making sure your fingers
are in contact with the conductive pad (2).
3. Place the index finger of the hand holding the tool
on the trigger (3).
4. Grip on both sides of the blade pin (4) with the other
hand.
Note
The Activ' Security LED turns solid red when
the tool has saved the user-related calibration
parameters.
5. Release the blade pin (4).
The tool emits a series of beeps.
Note
The Activ' Security LED turns blue.
20