PRUNING SHEARS C3X
26_176804-B
7.3. SUMMARY OF PRUNING SHEAR STATUS INDICATOR LIGHT CODES
Normal operation Codes
Use
Blinking green The pruning shears are on standby
Steady green The pruning shears are active
Error codes
Note
In the event of an error, the red indicator light lights up and flashes very rapidly, and the green indicator
light flashes a number of times depending on the error.
Green indicator light flashing once The pruning shears are in overcurrent or undervoltage
Green indicator light flashing twice Trigger position fault detected
Green indicator light flashing three times Motor rotation sensor fault detected
Green indicator light flashing four times Ball nut position sensor fault detected
Green indicator light flashing five times Tool overheating
Green indicator light flashing six times The electronic circuit board is damaged. Can only
occur at start-up
Green indicator light flashing seven times Fault detected with Activ' Security
Green indicator light flashing eight times Fault detected with the software