PL4/PSL4 Control System Installation Guide
SystemStart-Up
The following information describes basic start-up procedures. For more detailed troubleshooting
information,refertotheEasyTouchPL4/PSL4SystemsUser’sGuide(P/Nxxxxxx).Beforeyou
power up the Power Center check the following:
CheckElectronics
Check that the following plugs are seated correctly on the Personality board:
• Relayconnectors-FLTRPUMP - AUX1-AUX3
• TemperaturesensorsconnectorsWATER,SOLAR,AIR
• TransformerconductorharnessJ1attached to the EasyTouch PL4/PSL4 Control System
circuit board.
• HeatercontrolconnectorELECHTRor two-conductor screw terminal.
Refer to Summary Installation Steps (page 5) and Power Center System Wiring Diagrams, on page
Testingtheauxiliaryrelays
AfxtheauxiliaryrelaylabelstotheappropriatebuttonsontheEasyTouchPL4/PSL4Control
System control panel. If necessary, write the function on the control panel.
• Togglethelterpump,eachauxiliarycircuit,heaterandsolarandverifythefunction.Press
theSYSTEMCONTROLbuttontosetthesystemin“AUTO” mode when done.
System Test
The following describes how to test the Outdoor Control Panel to activate the heater, valves and
pumps. This test assumes that all system equipment has been properly installed and connected to
the Power Center.
TestingValveActuatorsandPumps
Use the following steps to test the valve actuators (CVA24T) for proper rotation for PSL4 Control
System (shared equipment).
To test the valve actuators and pump:
1. Power up the Power Center.
2. Press the MODEbutton on the Outdoor Control Panel until the SERVICEis displayed on
the screen.
3. Press the V(Valve) button to select POOL.
4. Press the F (FilterPump)buttontoactivatethelterpump.Waterwillberemovedfrom
the pool and returned to the pool.
5. Set both valve actuators (CVA-24T) for suction and return. Use the toggle switch on the
rear of the CVA-24 to withdraw and return water from the pool.
Note:Withthelterpumpoperating,ifthewaterisnotbeingremovedandreturnedtothe
pool, it may be necessary to reverse the RETURN with INTAKE plugs on the EasyTouch
PL4/PSL4 Control System circuit board.

Table of Contents

Other manuals for Pentair EASYTOUCH PL4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair EASYTOUCH PL4 and is the answer not in the manual?

Pentair EASYTOUCH PL4 Specifications

General IconGeneral
BrandPentair
ModelEASYTOUCH PL4
CategoryControl Systems
LanguageEnglish

Related product manuals