SystemStart-Up
The following information describes basic start-up procedures. For more detailed troubleshooting
information,refertotheEasyTouchPL4/PSL4SystemsUser’sGuide(P/Nxxxxxx).Beforeyou
power up the Power Center check the following:
CheckElectronics
Check that the following plugs are seated correctly on the Personality board:
• Relayconnectors-FLTRPUMP - AUX1-AUX3
• TemperaturesensorsconnectorsWATER,SOLAR,AIR
• TransformerconductorharnessJ1attached to the EasyTouch PL4/PSL4 Control System
circuit board.
• HeatercontrolconnectorELECHTRor two-conductor screw terminal.
Refer to Summary Installation Steps (page 5) and Power Center System Wiring Diagrams, on page
Testingtheauxiliaryrelays
AfxtheauxiliaryrelaylabelstotheappropriatebuttonsontheEasyTouchPL4/PSL4Control
System control panel. If necessary, write the function on the control panel.
• Togglethelterpump,eachauxiliarycircuit,heaterandsolarandverifythefunction.Press
theSYSTEMCONTROLbuttontosetthesystemin“AUTO” mode when done.
System Test
The following describes how to test the Outdoor Control Panel to activate the heater, valves and
pumps. This test assumes that all system equipment has been properly installed and connected to
the Power Center.
TestingValveActuatorsandPumps
Use the following steps to test the valve actuators (CVA24T) for proper rotation for PSL4 Control
System (shared equipment).
To test the valve actuators and pump:
1. Power up the Power Center.
2. Press the MODEbutton on the Outdoor Control Panel until the SERVICEis displayed on
the screen.
3. Press the V(Valve) button to select POOL.
4. Press the F (FilterPump)buttontoactivatethelterpump.Waterwillberemovedfrom
the pool and returned to the pool.
5. Set both valve actuators (CVA-24T) for suction and return. Use the toggle switch on the
rear of the CVA-24 to withdraw and return water from the pool.
Note:Withthelterpumpoperating,ifthewaterisnotbeingremovedandreturnedtothe
pool, it may be necessary to reverse the RETURN with INTAKE plugs on the EasyTouch