Installer Manual Fleck 3150 - NXT - Programming
62 / 122 Ref. MKT-IM-010 / B - 28.05.2018
6.5.6. System size
Set the number of valves to be connected (2 to 4 valves) in the system.
Note
Only visible in multiple valve systems and only present on the master #1 valve.
Options:
• 2 valves in the system;
• 3 valves in the system;
• 4 valves in the system.
6.5.7. Regeneration type
Select the regeneration type.
Options:
• time clock delayed: regeneration will take place, at the programmed regeneration start up time,
after predetermined delay set up in day elapsed (available only for system type 4);
• volume delayed: regeneration is requested when the volume of treated water reaches the
reserve capacity and will take place, at the programmed regeneration start up time (available
only for system type 4);
• volume immediate: regeneration is requested when the capacity is fully depleted. The
regeneration starts immediately (available for all system types).
H Adjust the system size with and .
→ Default setting: 2 valves.
I Press to validate the selection and advance to the next
parameter.
SYSTEM SIZE :
2 VALVES
J Set regeneration type with and .
K Press to validate the selection and advance to the next
parameter.
REGEN TYPE
TIME CLK DELAYED