6.5.19. Auxiliary relay / Chemical pump
Mandatory
The system can’t be set with auxiliary relay and chemical pump at the same time. Only one
option can be used.
6.5.19.1 Auxiliary relay
Set the relay output during regeneration.
Note
This parameter has two steps of settings. The first one activates the output, and the second
one deactivates the output. The time 00:00:00 correspond to the beginning of regeneration
time
AP Adjust the cycle time with , and .
AQ Press to validate the selection and advance to the next
parameter.
AR Repeat for each cycle.
1. Backwash: 10 min
CYCLE 1 00:10:00
BACKWASH
2. Draw/Slow rinse: 1 h 10 min
CYCLE 2 01:10:00
BRINE&SLOW RINSE
3. Fast rinse: 10 min
CYCLE 3 00:10:00
RAPID RINSE
4. Refill: 10 min
CYCLE 4 00:10:00
BRINE TANK FILL
5. Pause: not used
CYCLE 5 OFF
PAUSE & DELAY
AS Activate the relay with and .
→ Default setting: disabled
AT Press to validate the selection and advance to the next
parameter.
AU Set the relay activation time with , and .
AV Press to validate the selection and advance to the next
parameter.
AW Set the relay deactivation time with , and .
AX Press to validate the selection and advance to the next
parameter.
Disabled
AUXILIARY RELAY:
DISABLED
Relay enabled at the
beginning of regeneration
AUX RELAY OUTPUT
START: 00:00:00