Installer Manual Fleck 3150 - NXT - Programming
60 / 122 Ref. MKT-IM-010 / B - 28.05.2018
6.5.2. Entering master programming mode
6.5.3. Language setting
Select the displayed language.
Options:
•English;
French;
•German;
•Italian;
•Spanish.
FLOW METER
1.0" PADDLE -
Default flow meter type is based on the
valve type.
This screen will only display on the
lead (#1) unit for system types 6 & 7.
All other system types it will display for
all units.
1.0"
TURBINE
-
1.5" PADDLE -
1.5"
TURBINE
-
2.0"
TURBINE
-
3.0"
TURBINE
-
GENERIC -
PEAK FLOW
RATE
20 to 2’000 Lpm
Only displayed if “Generic” is chosen
for the flow meter.
ADD XXX LITERS
EVERY YYY
PULSES
1 to 255
XXX: number of litres
YYY: number of pulses
A Press and simultaneously for 5 seconds to enter the
master programming mode.
7#1 SRV* 08:26HR
VOLUME 20000L
B Select the language to be displayed with and .
C Press to validate the selection and advance to the next
parameter.
SELECT LANGUAGE:
ENGLISH
Parameter Options Definition Note