Connect AC power to the Power Center
Note: This Power Center is wired as an “All Pole Disconnect” System. Therefore a 3mm spacing is
required for all AC wiring entering the unit.
6. Use 12-14 AWG three conductor insulated wire for the main AC power connection. Connect the
Power Center to pool pump AC power source. The Power Center should be connected to the pump
motor switch or automatic timer. For system wiring information, see page 6.
7. Attach incoming GROUND wire to the ground lug inside the Power Center.
8. Earth Bonding (Grounding): Connect the earth wire to the GROUND BONDING LUG located on the
bottom of the Power Center enclosure. Earth bonding is necessary to ensure personal safety and safety of
equipment.
IMPORTANT: A number 8-guage (8.4 mm) wire is recommended when connecting the power supply to a
Permanent Earth Ground connection that is acceptable to the local inspection authority. Attach the
bonding point located on bottom of the Power Center to a Common Earth Bonding Point. Do not use the
IntelliChlor as the Common Bonding Point. Each piece of non-chlorinator pool equipment requiring a
ground should be bonded to the Common Approved Earth Bonding Point. Never ground pool pump to
Power Center.
9. Reinstall the Power Center cover and secure with the cover screw.
10. The Power Center installation is complete. For IntelliChlor operating information, refer to the
Connect incoming ground
wire to GROUND lug
Attach incoming power
wires (12-14 AWG 3-wire)
to Power Center
AC power wires
Conduit knockout
for AC power cable
source
Ground bonding lug