15
IntelliFloXF
™
and IntelliProXF
™
Variable Speed Pump Installation and User’s Guide
Set Speeds 1-8 in Schedule Mode
In Schedule mode, Speeds 1-8 can be programmed to run a certain speed at a certain time of
day. To run a scheduled speed, press Start/Stop. The screen will display “Running Schedules”
when it is ready to run a scheduled speed. If Start/Stop is pressed while a scheduled speed is
running, “Running Speed _” will be displayed (see image below).
1. Press Menu.
2. Use Up or Down arrows to scroll to “Speed 1-8”, then press Select.
3. Use Up or Down arrows
and press Select for the speed you wish
to set and schedule.
4. Press Select (display will be highlighted) and scroll to “Schedule”.
5. Press Enter.
6. Press Down arrow (“Set Speed” will display) and press Select to
change. Use the Up or Down arrow to adjust speed.
7. Press Enter to save the new speed.
8. Press the Down arrow again, “Set Start Time” will display. Press
Select -
the cursor will highlight the minute column.
9. Use the Up or Down arrow to change the time and the
Left or
Right
arrow to move cursor from minutes to hours.
10. Press Enter to save the new start time setting.
11. Press Down arrow - “Set Stop Time” will display. Press Select.
Repeat Steps 8-9 to set stop time.
12. Press Enter to save the new stop time setting.
13. Press Start/Stop.
The pump will prime and begin to run the programmed schedule at the specifi ed start time.
When running in Schedule or Egg Timer mode, the countdown time (T 00:01) showing the
hours and minutes remaining is displayed.
12:15p
Set Speed
Schedule
Note: The pump will not run the scheduled speeds until the Start/Stop button is pressed
(LED on) to place the pump in Schedule mode.
Note: When two speeds are scheduled during the same run time the pump will run the
higher RPM Speed regardless of Speed # in use.
Note: The most recent command, Manual or Schedule, takes priority regardless of speed
number RPM.
Programming Schedule for Constant Run
A speed cannot be programmed with the same start and stop times. To run a speed without
stopping, set the Start time one minute after the stop time.
Example: A single speed will run non stop if programmed with a Start Time of 8:00 AM and
a Stop time of 7:59 AM.
12:15p
750 RPM
T 1:05 150 WATTS
Running Speed 1
Pump Menu: Speeds 1-8
SPEED 1-8
MENU