EasyManua.ls Logo

Pentair IntelliFloXF - Page 40

Pentair IntelliFloXF
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
IntelliFloXF
and IntelliProXF
Variable Speed Pump Installation and User’s Guide
Problem Possible Cause Corrective Action
Inadequate circulation.
(For alert display
messages, refer to Alerts
and Warning on page 30).
Filter or pump basket dirty.
Suction/discharge piping is too small.
Speed is set too slow for proper fi ltration cycle.
Check trap basket; if plugged, turn pump off and
clean basket.
Check and clean pool fi lter.
Increase piping size.
Increase fi ltration run time
Electrical problem.
(For
alert display
messages, refer to Alerts
and Warning on page 30).
Could appear as a “Low Voltage” alarm.
PRIME ERROR may be displayed.
Could appear as “Over Heat” alert.
PRIME ERROR may be displayed.
Check voltage at motor terminals and at panel while
pump is running. If low, see wiring instructions or
consult power company.
Check for loose connections.
Check line voltage; if less than 90% or more than
110% of rated voltage consult a licensed electrician.
Increase ventilation.
Reduce ambient temperature.
Tighten any loose wiring connections.
Motor internal terminal overload protector is open.
Motor runs too hot. Turn power to motor off.
Check for proper voltage.
Check for proper impeller or impeller rubbing.
Mechanical Troubles
and Noise.
The pump motor is running but with loud noise.
Foreign matter (gravel, metal, etc.) in
pump impeller.
Cavitation.
If suction and discharge piping are not adequately
supported, pump assembly will be strained. Do not
mount pump on a wooden platform! Securely mount
on concrete platform for quietest performance.
Disassemble pump, clean impeller, follow pump
service instructions for reassembly.
Improve suction conditions.
Increase pipe size.
Decrease number of fi ttings.
Increase discharge pressure.
Pump does not respond
to IntelliTouch,
EasyTouch,
SunTouch, IntelliComm
commands.
Improper automation setup.
Communication network inoperative.
1. Be sure that the communication cable is
connected at both ends.
2. Check that the pump local address matches with
the address used in the IntelliTouch.
3. Check that the pump has been assigned a circuit
name on the IntelliTouch.
4. Ensure that the pump display says
“DISPLAY NOT ACTIVE”.
A defective device on the network can inhibit the
proper operation of other network device. Devices
should be disconnected sequentially until the
network starts working.
Problems and Corrective Actions, (Continued)

Table of Contents

Related product manuals