136
CUSTOM FUNCTIONS
Resetting the custom functions to the default
settings (Setting number [1]).
1. Set the mode dial to .
2. Hold down the AE lock button for
more than 2 seconds.
[CF] and [CL] will be displayed on
the LCD panel, and all the custom
functions will be reset to default
setting [1].
3. Set the mode dial to a position
other than , and
.
Setting the Custom Function
The setting for each custom function is explained below.
To display the custom function number and setting number,
see Basic Setting of Custom Functions on page 134.
[CF1] Setting the auto bracketing sequence
Custom Function number [CF1]
Setting number
[1] . . . .correct exposure under
exposure over exposure
[2] . . . .under exposure correct
exposure over exposure
[3] . . . .over exposure correct
exposure under exposure