P40 ED Input
43
Group
Parameter
Description
Machine type
User level
Setting range
Set value
9
939 Hold-back time (premature electrical
switchover) for feed adjustment when
switching on [ms]
1, 2, 3, 4, 5 B 10 - 200 30
968 Hold-back time (premature electrical
switchover) for feed adjustment when
switching off [ms]
1, 2, 3, 4, 5 B 10 - 200 30
969 Switch off position for presser foot
when thread is clamped at beginning
of seam
1, 2 , 3
4, 5
B
-
0 - 255
-
100
-
985 Switch on position for thread clamp 1, 2, 3, 4, 5 B 0 - 255 67
986 Switch off position for thread clamp 1, 2, 3, 4, 5 B 0 - 255 206
989 Thread clamp at beginning of seam
0 = Thread clamp off
1 = Thread clamp without presser foot
lift
2 = Thread clamp with presser foot lift
1, 2, 3, 4, 5 B 0 - 2 0
* = These parameters remain unchanged when the set parameter values are reset,