P70 ED Input
47
Group
Parameter
Description
Machine type
User level
Setting range
Set value
1
153 Start bartack(also see parameter 523)
ON = ornamental tack
OFF = standard tack
1, 2, 3 B ON - OFF ON
154 End bartack(also see parameter 523)
ON = ornamental tack
OFF = standard tack
1, 2, 3 B ON - OFF ON
157 Ornamental start tack with third seam
segment
ON = yes,
OFF = no
1, 2, 3 B ON - OFF ON
174 Stitches to output on 1, 2
3
-
B
-
1 - 255
-
4
175 Switch on time for output A 35 1, 2
3
-
B
-
0 - 2550
-
50
189 Delay time / switch on time t1output A 8 1, 2
3
-
B
-
0 - 2550
-
50
190 Delay time / switch on time 12 output
A 34
1, 2
3
-
B
-
0 - 2550
-
50
199 Speed for light barrier compensating
stitches
1, 2, 3 B 300 - 6400 1200
2
206 Interrupt /stop seam sector at fi xed
speed
ON = with pedal -2,
OFF = with pedal 0
1, 2, 3 B ON - OFF OFF
221 Max. speed for sewing programs 1, 2, 3 B 300 - 6400 1200
3
303 Needle position at end of seam sector
with end tack without trimming
ON = lowered
OFF = raised
1, 2
3
-
B
-
ON - OFF
-
OFF
304 Stitch compensation during feed chan-
geover
1, 2, 3 B 0 - 2550 30
307 Delay time till automatic switching off
of output after the machine stops [ms]
1, 2, 3 B 0 - 2000 50