Input P70 ED
48
Group
Parameter
Description
Machine type
User level
Setting range
Set value
3
311 Stop stitch counting
ON = with thread trimming
OFF = without thread trimming
1, 2, 3 B ON - OFF OFF
313 Programs as tack programs 1, 2, 3 A ON - OFF OFF
368 Start tack / ornamental start tack
ON = quadruple
OFF = double
1, 2, 3 B ON - OFF OFF
369 End tack / ornamental start tack
ON = quadruple
OFF = double
1, 2, 3 B ON - OFF OFF
4
400 Input puller
ON = switch operation (fl ip-fl op)
OFF = key operation
1, 2
3
B
-
ON - OFF
-
OFF
-
401 Input stroke adjustment
ON = switch operation
OFF = key operation
1, 2, 3 B ON - OFF
-
OFF
-
402 Speed for stroke adjustment 1, 2, 3 B 300 - 6400 1800
403 Delay for speed change at end of stroke
adjustment [ms]
1, 2, 3 B 0 - 2500 150
404 Speed for stroke adjustment 1, 2
3
B
B
0 - 255
0 - 255
5
1
418 Switch off of needle bars at end of seam
ON = both input controlled
OFF = iaw inputs
1, 2
3
B
-
ON - OFF
-
OFF
-
420 Puller function 1, 2, 3 B ON - OFF OFF
445 Stitches for puller delay 1, 2, 3 B 1 - 255 5
446 Input E 3 is:
1 = needle raised without trimming
2 = needle position change
3 = single stitch
4 = single stitch with shortened stitch
length
9 = alteration of needle position step by
step forwards
1, 2
3
B
B
1 -4
1
2
1