AxN Configurable Motion Control Platform
32
Motor Power Output Cable Sketch
Motor Power Output Installation
Wiring and Torque Specification
Connect the 4 wires of the motor power cable to the correspond terminals on the P2 port: U to A,
V to B, W to C and PE to PE.
Cable Fixing
Use a hose clamp to fix the cable on the cable support. The nominal torque to tight these terminals
is 0.5 ~ 0.6 Nāˆ™m.