C-863.12 Mercury Controller MS249E Version: 1.2.1 233
Acceleration in closed-loop operation (0xB)
Deceleration in closed-loop operation (0xC)
Velocity in closed-loop operation (0x49)
You can find details in the command descriptions (p. 125).
9.2.3 Saving Parameter Values in a Text File
The C-863.12 is configured via parameters, e.g., to adapt the mechanics connected. Changing
parameter values can cause undesirable results.
➢ Create a backup copy on the PC before changing the parameter settings of the C-863.12.
You can then restore the original settings at any time.
➢ Create an additional backup copy with a new file name each time after optimizing the
parameter values or adapting the C-863.12 to specific mechanics.
Parameter values saved in a text file on the PC can be loaded back to the C-863.12 in
PIMikroMove or PITerminal. The Send file... button is available for this purpose in the send
command window. Before loading into the C-863.12, the individual lines of the text files must
be converted into command lines that contain the corresponding SPA or SEP commands.
Requirements
✓ You have established communication with PIMikroMove or PITerminal between the C-
863.12 and the PC (p. 54).
Saving parameter values in a text file
1. If you use PIMikroMove, open the window for sending commands:
− Select the Tools > Command entry menu item in the main window or press the F4
key on the keyboard.
In PITerminal the main window from which commands can be sent is opened
automatically after establishing communication.
2. Get the parameter values from which you want to create a backup copy.
− If you want to save the parameter values from the volatile memory of the C-863.12:
Send the SPA? command.