Duplication of keys / remote controls
Procedure for the duplication of the remote
control for "Piaggio KeyLess" system.
A= Remote control
B= Master-Key
1. Check the initial conditions:
1.1 Battery voltage higher than > 12V,
1.2 It is necessary to have the Master-Key availa-
ble
1.3 It is necessary to have all remote controls to
be coded (including those already coded before
the procedure),
1.4 It is necessary to connect the PADS diagnosis
tool to the OBD connector of the vehicle, using a
specific tool.
Specific tooling
020922Y Diagnosis Tool
021017Y EOBD E5 diagnostics cable
2. Start duplication procedure before entering
Keyless Self-diagnosis using PADS:
2.1 Ignition key on "OFF",
2.2 Press the ignition key and at the same time
approach the master key (mechanical key) to the
Keyless control unit. (*)
2.3 Following the flashing of the hazard warning
lights, the ignition key can be turned to "ON" (**)
(*) The master key is equipped with an integra-
ted transponder and must be approached to
the inner side leg shield back plate at the top
left where the Keyless control unit is situated.
(**) From the moment the selector is turned to
the "ON" position, the Remote Control Pro-
gramming procedure must be started within
120 seconds (description in step 3. Otherwise,
the procedure must be started from step 2.