EasyManuals Logo

PIETRO FIORENTINI FE Series User Manual

PIETRO FIORENTINI FE Series
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
63
SERIES FE
LOW-PRESSURE GAS REGULATOR | COMMISSIONING | REV. 00
EN
Use, maintenance and warning manual
7.7.1.1 - REGULATOR RESET
To reset the underground version of the regulator with drum xed on the slam-shut valve lid, proceed as indicated in Tab.
7.40.:
Step Action
1 Undo the buttery screw (1) counterclockwise.
2 Remove the drum (3) from the brass tting (5).
3 Commission the equipment (see paragraph 7.4).
4 Check for the O-ring (2) on the brass tting (5).
5
Fit the drum (3) to the brass tting (5) so that the rubber tube (4) of the regulator vent is in a vertical position
inside the drum itself.
6 Turn the buttery screw (1) clockwise, tightening it fully to ensure locking and sealing of the system.
7 Make sure the drum (3) is in a horizontal position.
Tab. 7.40.
Fig. 7.15. Resetting of the underground regulator with drum xed on the slam-shut valve lid