2
nd
Digit –Operating zone for alarm and state of contact
0 Active “under” (independent or deviation alarm) or
“inside” (band alarm), Contact N.O.
1 Active “over” (independent or deviation alarm) or
“outside” (band alarm), Contact N.O.
2 Active “under” (independent or deviation alarm) or
“inside” (band alarm), Contact N.C.
3 Active “over” (independent or deviation alarm) or
“outside” (band alarm), Contact N.C.
4…7 As 0, 1, 2, 3 active ONLY in RUN (during cycle)
3
rd
Digit – Select process for alarm
Process 2
4
th
Digit –Type of alarm action on cycle
No action on cycle, no acoustic signal of buzzer, no
visualization on display
Output is commuted (change of relay or SSR contact).
Cycle stop with acoustic and visual signal
24
.
Output is commuted, buzzer is activated, display flashes,
cycle stops and controller goes to to STOP mode.
Only acoustic signal
Output is not commuted, buzzer i
s activated, display flashes.
P-14
Setpoint value for alarm no.1
-999/3000 digit (°C for temperature)
P-15
Setpoint value for alarm no.2
-999/3000 digit (°C for temperature)
P-16
Setpoint value for alarm no.3
da-999/3000 digit (°C for temperature)
P-17
Configuration digital input IN1
25
P-18
Configuration digital input IN2
Operating mode for digital inputs IN1..2. Impulse means contact
closed (or open) for min. 150msec.
1
st
Digit –Operating mode of digital input
Input not used
24
Visual signal for active alarm is or until is pushed
to confirm it.
25
Inputs not available if using RS485.