1
Input START at impulse (>= 150 msec)
2
Input STOP at impulse (>= 150 msec)
3
Input START/STOP at impulse (>= 150 msec)
4
RUN input when active. The controller executes the cycle
programmed on 3
rd
digit (or function selected on 4
th
digit)
until contact is closed (or open).
5
Temporary cycle block, flashing
(Normally connected to the door switching).
6
Cycle stop with acoustic and visual signal.
Visualize for IN1 or for IN2, buzzer is
active until is pressed.
7
Input HOLD.
Cycle is stopped and setpoint can be modified by frontal
keys.
8
Impulse input for step advancement (one step forwards)
during cycle.
2
nd
Digit Type of contact
0
Activation with closed contact
1
Activation with open contact
3
rd
Digit Function or cycle to activate
0
Activate function selected on 4
th
digit
1…9
Activate cycle no.1…9
4
th
Digit Special function to activate
0
“Simple controller”
1
Remote controller (if P-01/ 4
th
Digit selected as 0)
2
Manual control
(modify percentage of control output 0…100%)
3
Last executed cycle
4
Simple controller (also during cycle execution)
P-19
Configuration Auto-tuning and visualization of step
Select on which process Autotuning will be completed and which
values will be visualized in RUN mode.
1
st
Digit Configuration Autotuning
0
Autotuning only on process 1
1
Autotuning only on process 2
2
Autotuning both on process 1 and process 2
2
nd
Digit Control of heating elements power