Input START at impulse (>= 150 msec)
Input STOP at impulse (>= 150 msec)
Input START/STOP at impulse (>= 150 msec)
RUN input when active. The controller executes the cycle
programmed on 3
rd
digit (or function selected on 4
th
digit)
until contact is closed (or open).
Temporary cycle block, flashing
(Normally connected to the door switching).
Cycle stop with acoustic and visual signal.
Visualize for IN1 or for IN2, buzzer is
active until is pressed.
Input HOLD.
Cycle is stopped and setpoint can be modified by frontal
keys.
Impulse input for step advancement (one step forwards)
during cycle.
2
nd
Digit – Type of contact
Activation with closed contact
Activation with open contact
3
rd
Digit – Function or cycle to activate
0
Activate function selected on 4
th
digit
1…9
Activate cycle no.1…9
4
th
Digit – Special function to activate
Remote controller (if P-01/ 4
th
Digit selected as 0)
Manual control
(modify percentage of control output 0…100%)
Simple controller (also during cycle execution)
P-19
Configuration Auto-tuning and visualization of step
Select on which process Autotuning will be completed and which
values will be visualized in RUN mode.
1
st
Digit – Configuration Autotuning
Autotuning only on process 1
Autotuning only on process 2
Autotuning both on process 1 and process 2
2
nd
Digit – Control of heating elements power