Start guide
DRR245
Controller
Question and Answer IconNeed help?

Do you have a question about the Pixsys DRR245 and is the answer not in the manual?

Pixsys DRR245 Specifications

General IconGeneral
BrandPixsys
ModelDRR245
CategoryController
LanguageEnglish

Summary

Introduction

Safety Guide Lines

Model Identification

Technical Data

General Data

Specifications for displays, operating temperature, sealing, material, and weight of the controller.

Hardware Data

Details on analogue input, relay output, and SSR/V/mA output specifications.

Software Data

Information on regulation algorithms, proportional band, integral and derivative times, and controller functions.

Dimensions and Installation

Electrical Wirings

Wiring Diagram

Diagram illustrating the electrical connections for the DRR245 controller's terminals.

Power Supply

Details on the switching power supply for the DRR245 controller.

AN1 Analogue Input

Instructions for connecting thermocouples and thermoresistances to the AN1 input.

Linear Input Example

Illustrations for connecting Volt/mA sensors using different wiring methods.

Serial Input

Information on RS485 Modbus RTU communication and wiring.

Relay Q1-Q2 Output

Details on the capacity and life curve for relay outputs Q1 and Q2.

SSR Output

Instructions for configuring and using the SSR output.

mA;Volt Output

Configuration for mA or Volt linear output and optional external power supply.

Current Transformer Input

Specifications and usage for the current transformer input.

Digital Input 1

Usage and short-circuiting for Digital Input 1.

Digital Input 2

Combined use of digital input and TA input for specific sensors.

Display and Key Functions

Numeric Indicators (Display)

Describes the normal display of process and setpoint values.

Meaning of Status Lights (Led)

Defines the meaning of various status LEDs on the controller.

Keys

Details the functions of the controller's front panel keys.

Controller Functions

Modifying Setpoint Values

Instructions on how to change the main setpoint and alarm setpoint values.

Auto-Tuning

Explanation of the auto-tuning procedure for controller parameter calculation.

Manual Tuning

Guide to manual tuning procedures for PID algorithm work parameters.

Automatic Tuning

Details on how automatic tuning activates and its parameters.

Soft-Start

How to use the Soft-Start function to reach setpoint with a gradient.

Automatic;Manual Regulation

Function to select automatic or manual command of the output percentage.

Pre-Programmed Cycle

How the pre-programmed cycle function activates and its operation.

Memory Card (optional)

How to duplicate parameters and setpoints using the memory card.

Latch On Functions

Loop Break Alarm

Digital Input Functions

Dual Action Heating-Cooling

Serial Communication

Enter Configuration Parameters

Loading Default Values

Procedure to restore the instrument's factory settings.

Table of Configuration Parameters

Input and Setpoint Configuration

Configure sensor type, decimal point, and setpoint limits.

Linear Input and Calibration

Set linear input ranges, latch function, offset, and gain.

Command and Control Parameters

Configure command output state, reset, LEDs, hysteresis, and delay.

PID and Output Control Settings

Set PID parameters, setpoint protection, and output power limit.

Alarm 1 Configuration Options

Configure Alarm 1 selection, state, reset, LED, hysteresis, delay, protection.

Alarm 2 Configuration Options

Configure Alarm 2 selection, state, reset, LED, hysteresis, delay, protection.

Current Transformer and Loop Break Alarm

Configure current transformer input and loop break alarm settings.

Cooling PID and Fluid Settings

Configure cooling fluid type, PID parameters, and cycle time.

Conversion Filter and Frequency

Set ADC filter and sampling frequency for input signals.

Visualization and Tuning Settings

Configure display visualization and PID tuning methods.

Operating Mode and Digital Input

Select operating mode and configure digital input functions.

Gradient and Maintenance Time

Configure rising gradient and maintenance time for cycles.

Visualization Types and Degrees

Select display visualization types and temperature units.

Retransmission and Baud Rate

Configure output retransmission and serial communication baud rate.

Serial Communication Settings

Configure slave address, serial delay, and output percentage limits.

Alarm Intervention Modes

Absolute Alarm (A. AL. selection)

Absolute alarm with controller in heating or cooling functioning.

Absolute Alarm Referring to Setpoint

Absolute alarm referring to the command setpoint.

Band Alarm

Band alarm hysteresis value greater or less than '0'.

Upper Deviation Alarm

Upper deviation alarm value of alarm setpoint.

Lower Deviation Alarm

Lower deviation alarm value of alarm setpoint.

Table of Anomaly Signals

Configuration EASY-UP

Notes; Updates