EasyManua.ls Logo

PLANET ECLIPSE LV1.6 - Page 31

PLANET ECLIPSE LV1.6
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FIG-1
FIG-3
FIG-2
FIG-4
31
ELECTRONICS
USER INTERFACE PARAMETERS
FIG-1 - FILTER MENU
The FILTER menu parameters are used to tune the
marker software lters to prevent the marker from
ring unless all of the necessary conditions are
met. Factory default settings are suitable for most
set-ups however, certain loader and trigger
set-ups may require lter adjustments.
FIG-2 - DEBOUNCE PARAMETER
This sets the amount of trigger bounce that is
allowed and can be set from level 1 to level 9.
Changing this parameter directly changes the
PULL PT, PULL TM, RELEASE PT and
RELEASE TM.
> LEVEL1: Least ltering (most bounce).
> LEVEL9: Most ltering (least bounce).
FIG-3 - EMPTY PARAMETER
This sets the amount of time that the breech has
to be empty before the marker registers that it is
actually empty.
This can be set between 1.0 and 20.0 milliseconds
in 0.1 increments.
FIG-4 - FULL PARAMETER
This sets the amount of time that the breech has
to be full (paintball in place) before the marker
registers that it is actually full.
This parameter can be set between 1.0 and 20.0
milliseconds in 0.1 increments.

Related product manuals