Configuring Front Panel Displays ION 8000 Series User Guide
Page 166 Chapter 15 - Displays
To configure parameter titles
The parameter value on a display screen is the value of an output connected to the
Display module Source input register. By default, the displayed parameter’s title is
the name of the output connected to the Source input. The Display module Source
Title setup register lets you change the default to a title that better describes your
system. For example, if “KWh Net” is linked to the first Source input, you could
change its display name by setting Source 1 Title to “KWh Net West.” A maximum
of 25 characters is permitted.
See “Changing TEST Mode Timeout” on page 178 for information on configuring
TEST mode display timeouts.