Transporting the Server Important Notes
specified by Fujitsu Siemens Computers. The correction of interferences
caused by such unauthorized modification, substitution or attachment will be the
responsibility of the user.
The use of shielded I/O cables is required when connecting this equipment to
any and all optional peripheral or host devices. Failure to do so may violate FCC
and ICES rules.
3.4 Transporting the Server
V CAUTION!
Only transport the server to the new site in its original packaging or in
packaging that protects it from knocks and jolts. Do not unpack the server
until it is at its installation location.
If you need to lift or transport the server, ask other people to help you.
3.5 Notes on Installing in the Rack
V CAUTION!
When connecting and disconnecting cables, observe the relevant
notes in the chapter „Important notes“ in the technical manual for the
corresponding rack. The technical manual is supplied with the corre-
sponding rack.
Make sure when installing the rack that the anti-tilt mechanism is
properly mounted.
For safety reasons, no more than one unit may be removed from the
rack at any one time during installation and maintenance work.
If several units are removed from the rack at the same time, there is
a risk that the rack will tilt forward.
The rack must be connected to the power supply by an authorized
specialist (electrician).
If the rack model is integrated in an installation that receives power
from an industrial (public) power supply network with the IEC309
connector, the (public) power supply protection must comply with the
requirements for non-industrial (public) power supply networks for the
type A connector.