A26361-K878-Z102-2-7619 23
Hardware Installation Installing/Removing the Server into/from the Rac
4.3 Installing/Removing the Server into/from
the Rack
V CAUTION!
●
Please note the safety instructions in
chapter “Important Notes” on
page 11 and in section “Notes on Installing in the Rack” on page 18.
● The rack can tip over when more than one slide-in module is pulled
out.
V CAUTION!
No cable management is available for the server!
Before removing the server from the rack, all cables connected on the
server must be unpluged from the sockets. Proceed as follows:
Ê Close all applications and shut down the operating system in a
orderly manner.
Ê Switch OFF the server.
Ê Unplug all cables from the server.
Ê Remove the server.
4.3.1 Requirements of the Rack
The rack systems of the Fujitsu Siemens Computers (PRIMECENTER Rack,
DataCenter Rack and 19-Inch (Classic) Rack) support fully the installation of the
PRIMERGY server systems. The installation into the at present usual rack
systems of different foreign manufacturers (3rd-Party Rack) is supported to
large part.
To accommodate the ventilation concept and ensure proper ventilation of the
components in the rack, any unused areas must be closed using dummy covers.
The power is supplied via the socket strips available in the rack.
The main features of the rack systems of the Fujitsu Siemens Computers are: