24 A26361-K878-Z102-2-7619
Installing/Removing the Server into/from the Rack Hardware Installation
PRIMECENTER Rack
– Frontally bolted telescopic rails.
The rails are provided with a linear alignment possibility to ensure also an
adjustment to different rack depths.
DataCenter Rack
– Frontally or laterally bolted telescopic rails (except within the rear left area
where a support angle is used).
Classic (19-Inch) Rack
– Laterally bolted telescopic rails.
The mounting of the rails in the different racks is described in the next sections.
To rack systems of different foreign manufacturers the following applies:
3rd-Party Rack
Certain boundary conditions are to be fulfilled:
– Installation dimensions (see the dimensions shown in figure 2 on page 26):
1 rack front side
2 rack rear side
A rack depth (comparison PRIMECENTER Rack 940/1000 mm)
B rack width (comparison PRIMECENTER Rack 700 mm)
C clearance of the 19-inch installation level
C1 front 19-inch installation level
C2 rear 19-inch installation level
D area for cable routing (cable area depth) and ventilation
E area for front panel and ventilation
F right and left area for support systems
P PRIMERGY installation depth
a1 front left support upright
a2 front right support upright
b1 rear left support upright
b2 rear right support upright