OPERATION
UM-PSPC-06-E/10-2012 USER MANAUL PSPC Page 51 of 99
OPERATION ADJUSTMENTS
AIR SUPPLY
Normally the Prinzen systems need an air
pressure of approximately 6 bars (make sure
your compressed air supply is between 8 and
10 bars).
Adjust this air pressure with the primary
pressure regulator. Pull the knob (1) up and
turn it to change the air pressure. Press the
knob down to lock it again.
On the air pressure regulator a manual
ON/OFF switch (2) is positioned. Move the
switch towards the regulator to switch the air
ON. Move away from the regulator to switch
the air OFF.
GATE BLOCKERS
Gate blockers prevent the possibility of 2
smaller eggs entering 1 gate.
When smaller eggs are produced keep all gate
blockers in the infeed gates (8).
When the produced eggs are becoming bigger
remove every other gate blocker (9).
As soon as most of the produced eggs are big
and the infeed of eggs get stuck by the gate
blockers, remove all gate blocker (10).
1
2
8
9
10