OPERATION
Page 64 of 99 USER MANUAL PSPC UM-PSPC-06-E/10-2012
SERVICE MENU EGG BELT CONTROL
In this menu the timers for controlling the automatic start and stop of the egg-collecting conveyor are
adjustable. Follow below procedure to change the start delay or stop delay:
- Press F6 to be able to change the value of the parameter.
- Repeat pressing F3 until all digits are 0.
- Press F4 to increase the most right digit until the required digit value is reached.
- Press F3 to shift this digit to the left.
- Repeat the above until the required start delay or stop delay is visible on the display.
- Press F6 to acknowledge this value.
Edit start delay:
The start delay is the time between the egg pressure sensors no longer detecting eggs and the restart
of the egg-collecting conveyor. When this start delay is too short the egg-collecting conveyor stops
and starts too often. When this timer is too long, the packer stops once in a while because it takes too
long before eggs are present in all gates.
Edit stop delay:
The stop delay is the time between the egg pressure sensors detecting eggs and the stop of the egg-
collecting conveyor. When this stop delay is too short, the egg-collecting conveyor stops just after an
egg is detected. When this timer is too long, too many eggs enter the infeed conveyor causing too
much pressure on the gates.
SERVICE MENU SET REPETITION DENESTER
When the denester attempted to place a tray on the output conveyor, but no tray was detected on this
conveyor, the denester repeats a number of times trying to place a tray on the conveyor before
sending an alarm message to the display (denester fault, no tray out). The amount of repetitions the
denester makes is set with this parameter.
Press F6 to be able to change the value of the parameter.
Pressing F3 resets the number of repetitions to 0.
Pressing F4 increases the number of repetitions.
SERVICE MENU SET STACKER HEIGHT
This menu is used to set the stacker height for the optional automatic tray stacker. The amount of
trays this stacker stacks is adjustable with this parameter.
Press F6 to be able to change the value of the parameter.
Pressing F3 resets the number of trays to 0.
Pressing F4 increases the stacked number of trays.