MAINTENANCE
UM-PSPC-06-E/10-2012 USER MANAUL PSPC Page 71 of 99
RECOMMENDED CLEANING AGENT
Prinzen customers often use Hatchonet cleaning agent for hatcheries for cleaning their systems. The
supplier of this cleaning agent is Cid lines. For safe and correct use of this cleaning agent, contact Cid
lines. Visit their website to find a local dealer: www.cidlines.com.
Prinzen recommends this cleaning agent instead of others but we cannot verify the correct use of it
and thus we cannot guarantee a good cleaning result and avoiding negative influences of it on our
systems.
GENERAL CLEANING PROCEDURE
Before actually starting to clean the system, first follow below steps:
- See to it that all eggs are removed by letting the machine run empty.
- Switch off the system and secure it against accidental switching on.
- Clean the complete system with compressed air, a vacuum cleaner and a plastic scraper.
- Remove persisting scrap with a moistened cloth.
- Check the condition of the system during cleaning.
CAUTION!
When using warm water to moisten a cloth, make sure the temperature of the water is below 45°C. Above this
temperature it is possible to incinerate body parts.
ATTENTION!
Do not use abrasive cleaning detergents or utensils on non-longwearing parts.
Do not use aggressive cleaning products. Use cleaning product with a PH value higher than 6. Do not use
chlorinated cleaning agents. After cleaning with a cleaning product, rinse off with plenty of water.
ATTENTION!
The system is NOT designed for wet cleaning. Do NOT clean the system with water and certainly NOT with a high
spraying pistol. Only use moistened cloths for cleaning.
Do NOT clean bearings, printers, robots, electrical parts and pneumatic parts with water.
Perform the cleaning according the advices and intervals as described in the Preventive maintenance
instructions further on in this chapter.
TIP!
The cleaning advices and intervals described in this manual are general. For your specific products and production
process the cleaning schedule may need alteration. During the first production months observe the performance of
the system and the influence of contamination on the product quality and production process and (if necessary)
change the cleaning methods and schedules.
AFTER CLEANING
When the cleaning duties are finished, follow steps below:
- Consult your maintenance engineer in case of questions about the condition of parts.
- Blow dry the system, the system must be absolutely dry before putting it back into operation.
- Lubricate moving parts that have been cleaned.
- Remove excess grease after lubrication.
- Make sure all cleaning utensils are removed from the machine.