• PH PROBE:
Unscrew the white cap and withdraw the probe
from its vial of liquid. Remove the black o-ring and
the white cap from the probe and replace them on
the vial (keep
this to winterize
the probe).
Unscrew the
black nut from
the tee, be
careful not
to lose the
removable
parts.
Thread the black ring, the metallic washer and the
compression ring onto the body of the probe.
Make sure that the o-ring is correctly positioned on
the tee union.
Push the end of the probe into the union until the
end of the probe is located in the centre of the pipe
Screw the nut
union, and
check that the
probe cannot
be removed by
pulling gently.
two probes to the
electrical panel
as indicated in the diagram on page 11.
IMPORTANT! The active tips of the probes must
always be immersed, see the section on hydraulic
connections.
• INSTALLING THE ELECTRICAL/ CONTROL PANEL
Reminder:
The control panel is IP56 rated (according to the
standard EN 60529). It will not be damaged by
splashing, however it should be located at least 3.5
metres from the pool.
If this is not possible, it may be positioned closer to
the pool, but under no circumstances closer than 2
metres, subject to the condition that its power cable
is directly connected to a 30mA residual current
device (as stipulated in the standard NF C 15-100).
the plant room using the 2 mounting brackets.
For added safety, position the panel at a height
inaccessible to children.
IMPORTANT !
- To allow the panel to cool properly, do not obstruct
- Do not install the panel is a closet or any other
place where inadequate ventilation could cause the