46/84
2015/02 - Indice de révision : B - Code : 29650
• PERIODIC INJECTION:
•
• press the button to enter pH REDUCING –
AUTO mode.
• PUNCTUAL INJECTION:
•
• press the button three times to enter pH
REDUCING – MANUAL mode
• Using the arrow keys and elect an injection
volume LVL,
LVL = 1 -> volume = 70 cm3
A few seconds after the volume is set, the pump
will begin to inject the selected volume. To cancel
pump.
IX. WARNING AND ERROR MESSAGES:
• SALT CONCENTRATION TOO LOW OR TOO HIGH
within acceptable limits , the salt
gauge will rise to a point within
the ticked ( ) zone.
Salt concentration too low:
Below a salt concentration of 1 g/litre, the cell
will stop producing Chlorine and the message
NO CELL is displayed at the bottom of the LCD
screen LCD.
IMPORTANT :
build up of scale on the electrodes rather than a
real lack of salt. In the event of a low salt warning,
check that the electrodes are clean and check the
salt concentration with a suitable tester in case of
doubt.
A fault temperature sensor could also cause a
low salt warning
Salt concentration too high:
At a salt concentration above 10.0 g/litre, the cell
stops producing Chlorine and the icon is displayed
to the right of the LCD screen. The high salt icons
blink continuously and the message HIGH SALT
or SHRT CELL is displayed at the bottom of the
screen.
The salt concentration is lowered by renewing
a volume of pool water.
If the salt concentration is higher than 6.5
g/l, a volume of the pool water must be
renewed immediately in order to bring the salt
concentration down to an acceptable level.
• ELECTRICAL PROBLEMS WITH THE CELL
2 types of electrical problems are signalled if
detected:
• Short circuit in the cell power supply circuit: the
message SHRT CELL is displayed at the bottom
of the screen.
Cut power to the control panel
carefully, starting at the terminal in the connection
Low salt, the gauge is below the ticked range.
The word 'Low' and a salt shaker appear:
• 2
and 3 g/litre
• Blinking if the salt concentration is bewteen
1 and 2 g/litre
High salt, the gauge is above the ticked
range. in addition:
• between 5.5 and 6.5 g/litre, the message
"High" is displayed.
• between 6.5 and 8.0 g/litre, the icon is
displayed.
• Above 8.0 g/litre, both the message and
the icon blink.