40/84
2015/02 - Indice de révision : B - Code : 29650

m). The two tabs keep each pair of connectors
correctly assembled with respect to each other.
       
lightly on each connector.
NEVER MODIFY, SHORTEN OR LENGTHEN
THE CABLES.
WIRING IN THE CONTROL PANEL :
Horloge
Disjoncteur magnéto-
thermique pompe
Contacteur*
230 V ~
Bornier alimentaion
coret EES
Auto
Disjoncteur, porte-
fusible, ou secionneur


N/LN1 = permanent neutral
LN2 = permanent live (panel and pH-Clear)
LD2 = slaved live (cell)
*Nota bene: to avoid electrical disturbances when the pump starts and stops, the EES power cables

as illustrated in the diagram, or failing this a contactor with 2 power inputs/ outputs for the pump and

The power rating of the panels are as follows:
Panels for pools up to 80 m3 = 0.6 A
Panels for pools up to 150 m3 = 1.2 A
To connect the control panel to the contactor and the contactor to the mains, we recommend that you
use cables with a strand cross section of 1.5 mm
2
. If the cable is very long, use one with a strand cross
section of 2.5 mm
2
.
Circuit breaker, fuse housing or switch
EES panel power supply terminal
Magnetotheral circuit breaker,
pump
Switch*
Timer